Skip to content

SMP Data: first fragments are truncated #92

@XavierBoniface

Description

@XavierBoniface

The first L2CAP fragments of SMP packets are truncated when capturing HCI logs using WPR or BTVS.

Log 1 (btvs) = DellLatitudeE7240.zip
Captured with Windows 11 on a Dell Latitude E7240 laptop with intel 7260 Bluetooth chip (see report_2021-7-12_19-2-48.txt)
See red and green markers in the HCI overview (Note: because of a sniffer issue they only appear in the Instant Timing view, then one can double click from there on the packet to make them appear in the HCI Injection Overview) : first fragments are truncated, others are not.
Here the air log was captured at the same time and we can map those HCI packets to the L2CAP packets exchanged over the air (yellow markers). Pairing was successful, what was exchanged on HCI was correct, it must be just btvs that truncates the data.

Log 2 (etl) = etl: BthTracing.zip and extracted cfa: BthTracing.btt.zip
Captured with Windows 10 PRO 21H1 on a Dell Vostro 3591 with Qualcomm 11ac QCA 9377 Bluetooth chip, driver version 10.0.0.953
Here we don't have the air logs and this is the problem: we cannot see what the SMP problem was :-(

Note: this is somewhat similar to #85.