Battery_temp_sensor_fix #131
Closed
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
This Fix removes the issue as described in #130.
For some reasons BAT_DCB_NR_SENSOR returns high values (35 in my case), while the actual S10X Compact has only 5 temperature sensors.
For robustness measures, this fix checks the amount of acual received temperature values and uses the smaller amount, to not overshoot the array of received sensor values.